OBH-IoT Device Inventory

Device Location IP Address Firmware Phase
Zigbee Coordinator 1 Main Site 194.1.1.101 ZZ 0.9.9 (Mar 2023) -
Zigbee Coordinator 2 DR-Site (หลัก) 194.1.1.102 ZZ 0.9.9 (Mar 2023) -
Zigbee Coordinator 3 DR-Site (แม่สาย) 194.2.1.1 ZZ 0.9.9 (Mar 2023) -
Zigbee Coordinator 4 DR-Site (เชียงของ) 194.3.1.1 - Phase 3
Zigbee Coordinator 5 DR-Site (หลัก ดาดฟ้า-B) 194.1.1.134 - Phase 4
Zigbee Coordinator 6 DR-Site (หลัก ดาดฟ้า-K) 194.1.1.135 - Phase 4
Zigbee Coordinator 7 Main Site (ห้อง UPS) - - Phase 4
Zigbee Coordinator 8 DR-Site (หลัก) spare 194.1.1.137 - Phase 4
Device Location IP Address Firmware Power
Water Level 1 Main Site (บ่อใต้ดิน B - ถังพักน้ำใหญ่) 194.1.1.103 Tasmota AC 220V
Water Level 2 Main Site (บ่อใต้ดิน K - ก่อนสูบขึ้นดาดฟ้า) 194.1.1.104 Tasmota AC 220V
Water Level 3 Main Site 194.1.1.105 Tasmota AC 220V
Water Level 4 Main Site 194.1.1.106 Tasmota AC 220V
Water Level 5 Main Site 194.1.1.107 Tasmota AC 220V
Water Level 6 Main Site 194.1.1.108 Tasmota AC 220V
Device Location IP Address Firmware Notes
Water Tank1 Lamp Main Site (บ่อใต้ดิน B) 194.1.1.223 Tasmota ไฟระดับน้ำ
Water Tank2 Lamp Main Site (บ่อใต้ดิน K) 194.1.1.227 Tasmota -
Water Tank3 Lamp Main Site (บ่อดาดฟ้า K) 194.1.1.228 Tasmota -
Water Tank4 Lamp Main Site (บ่อดาดฟ้า B) 194.1.1.226 Tasmota -
Tap Water Tank1 Lamp Main Site (บ่อใต้ดิน B) 194.1.1.229 Tasmota ฉุกเฉินอัตโนมัติ
Tap Water Tank2 Lamp Main Site (บ่อใต้ดิน K) 194.1.1.230 Tasmota ฉุกเฉินอัตโนมัติ
Tap Water Tank1 Controller Main Site (บ่อใต้ดิน B) 194.1.1.231 Tasmota ฉุกเฉินอัตโนมัติ
Tap Water Tank2 Controller Main Site (บ่อใต้ดิน K) 194.1.1.232 Tasmota ฉุกเฉินอัตโนมัติ
Device Location IP Address Firmware Phase
Magnetic Controller AC 1/1 Main Site 194.1.1.109 Tasmota -
Magnetic Controller AC 1/2 Main Site 194.1.1.110 Tasmota -
Magnetic Controller AC 2/1 Main Site 194.1.1.111 Tasmota -
Magnetic Controller AC 2/2 Main Site 194.1.1.112 Tasmota -
Magnetic Controller AC 3/1 DR-Site (เชียงของ) 194.3.1.2 Tasmota Phase 3
Magnetic Controller AC 3/2 DR-Site (เชียงของ) 194.3.1.3 Tasmota Phase 3
Magnetic Controller AC 4/1 Main Site 194.1.1.138 - Phase 4
Magnetic Controller AC 4/2 Main Site 194.1.1.139 - Phase 4
Magnetic Controller AC 5/1 DR-Site (แม่สาย) 194.2.1.4 - Phase 4
Magnetic Controller AC 5/2 DR-Site (แม่สาย) 194.2.1.5 - Phase 4
Magnetic Controller AC 6/1-8/2 TBD TBD - Pending
Device Location IP Address Phase
IR Blaster 1 Main Site 194.1.1.113 -
IR Blaster 2 DR-Site (หลัก) 194.1.1.114 -
IR Blaster 3 DR-Site (แม่สาย) 194.2.1.2 -
IR Blaster 4 DR-Site (เชียงของ) 194.3.1.4 Phase 3
IR Blaster 5 Main Site (ห้อง UPS) 194.1.1.140 Phase 4
IR Blaster 6 DR-Site (แม่สาย) 194.1.1.141 Phase 4
IR Blaster 7-9 TBD TBD Pending
Device Location IP Address Firmware Notes
Temp 1 Main Site (DC) 194.1.1.115 Tasmota (Replacement) -
Temp 2 Main Site (DR) 194.1.1.116 ESPHome -
Temp 3 DR-Site (แม่สาย) 194.2.1.3 ESPHome -
Temp 4 DR-Site (เชียงของ) 194.3.1.5 ESPHome Phase 3
Temp 5 Main Site 194.1.1.125 Tasmota -
Temp 6 Main Site 194.1.1.126 Tasmota -
Temp 7 Main Site 194.1.1.127 Tasmota -
Temp 8 Main Site 194.1.1.128 Tasmota -
Temp 9 Main Site 194.1.1.129 Tasmota -
Temp 10 Main Site 194.1.1.130 Tasmota -
Temp 11 Main Site 194.1.1.142 - -
Temp 12 DR-Site (แม่สาย) spare - - -
Temp 13 Main Site (คลังยา) 194.1.1.143 Tasmota -
Temp 14 Main Site (คลังเภสัชภัณฑ์) 194.1.1.144 Tasmota -
Temp 15 Main Site (คลังน้ำเกลือ) 194.1.1.145 Tasmota -
Temp 16 Main Site (ห้องเก็บเวชภัณฑ์ OR เล็ก) 194.1.1.146 Tasmota -
Temp 17 Main Site (ห้องเก็บเวชภัณฑ์ OR ใหญ่ #1) 194.1.1.147 Tasmota -
Temp 18 Main Site (ห้องเก็บเวชภัณฑ์ OR ใหญ่ #2) 194.1.1.148 Tasmota -
Device Location IP Address Firmware Notes
EMON 3P #1 Main Site (UPS อาคารหมอกัมพล) 194.1.1.117 Tasmota Meter code: 1000, UPS power
EMON 3P #2 Main Site (UPS อาคารหมอบริกส์) 194.1.1.118 Tasmota ตู้ Main, UPS power
EMON 3P #3 Main Site (MDB-K1) 194.1.1.150 Tasmota Meter code: 1000, MDB power
EMON 3P #4 Main Site (MDB-K2) 194.1.1.151 Tasmota MDB power
EMON 3P #5 Main Site (MDB-B1) 194.1.1.152 Tasmota MDB power
Device Location IP Address Firmware Notes
Solar Logger #1/1 (EW11) Main Site (Building K, Inverter 1) 194.1.3.246 EW11 SUN2000-60KTL-M0, Modbus ID=1
Solar Logger #1/2 (Waveshare) Main Site (Building K, Inverter 2) 194.1.1.119 Waveshare SUN2000-60KTL-M0, Modbus ID=1
Solar Logger #2 (Waveshare) Main Site (Building B) 194.1.1.120 Waveshare SUN2000-60KTL-M0, Modbus ID=1
RS485 Logger #1 Main Site (Building K, Inverter 1) 194.1.1.153 Waveshare SSID: Inverter-K1
RS485 Logger #4 Main Site 194.1.1.154 Waveshare SSID: RS485_04
RS485 Logger #5 Main Site 194.1.1.155 Waveshare SSID: RS485_05
RS485 Logger #6 Main Site 194.1.1.156 Waveshare SSID: RS485_06

Solar Inverters:

  • Building K: SUN2000-60KTL-M0 (x2) at 194.1.1.1
  • Building B: SUN2000-60KTL-M0 at 194.1.1.2
  • Building HN (หอพัก): SUN2000-20KTL-M5 at 194.1.1.3
Device Location IP Address Firmware Notes
Pump 01 - Controller Main Site 194.1.1.121 Tasmota Generator power
Pump 01 - Temp & Door Main Site 194.1.1.122 Tasmota Generator power
Pump 01 - Mode Light Main Site 194.1.1.131 Tasmota Generator power
Pump 02 - Controller Main Site 194.1.1.123 Tasmota Generator power
Pump 02 - Temp & Door (SPARE) Main Site 194.1.1.124 Tasmota Generator power
Pump 02 - Mode Light Main Site 194.1.1.132 Tasmota Generator power
Pump 02 - Temp & Door Main Site 194.1.1.133 Tasmota Generator power
PUMP-03 Main Site 194.1.1.157 Tasmota Pump บาดาล Spare
PUMP-04 to PUMP-08 Main Site 194.1.1.158-162 Tasmota ชุดม่านอากาศ
PUMP-09 Main Site 194.1.1.163 Tasmota -
Device Location IP Address Firmware Notes
Chime Controller Main Site 194.1.1.222 Tasmota -
Chime Controller (spare) Main Site 194.1.1.236 Tasmota สำรองเปลี่ยนทดแทน
LPG Station Main Site 194.1.1.224 Tasmota -
LPG Alarm Main Site 194.1.1.225 Tasmota -
Nitrous Controller Main Site 194.1.1.237 ESPEasy -
Nitrous Controller (spare) Main Site 194.1.1.238 ESPEasy -
Nitrous Controller (new) Main Site 194.1.1.241 ESPEasy -
Odor Detection Station Main Site 194.1.1.237 Custom Thingspeak integration
ZKTecho TimeScan Main Site 194.1.2.20 ZKEcho Time attendance
Google Nest Mini 1-3 Main Site 194.1.1.233-235 Google Voice assistant
UPS-EcoFlow3Plus Main Site 194.1.1.247 EcoFlow Power station
SONOFF PM2.5 1-2 Main Site 194.1.1.248-249 SONOFF Air quality
SONOFF CO2 1-2 Main Site 194.1.1.250-251 SONOFF Air quality

21 battery-powered ESP8266 devices (MC01A-MC21A) running Arduino IDE firmware. IP range: 194.1.1.200-221. MQTT topics: cart/01 through cart/21.

Device Location IP Address Notes
OBHIoTM1-PC Main Site 194.1.2.10 AnyDesk: 984 855 944
OBHIoTM1-MONITOR Main Site 194.1.2.11 Display
OBHIoTM2-PC Main Site 194.1.2.12 AnyDesk: 439 370 230
OBHIoTM2-MONITOR Main Site 194.1.2.13 Display

6x TASMOTA-SIGNAL-TEST devices (194.1.2.14-19) and 3x Tasmota test devices (194.1.1.239-242) for system testing.

No Device Model Location Description
1-7 Door Sensor 1-7 Xiaomi/Aqara All Sites Door contact sensors on server rooms
8 Tuya TS0225 ZG-205ZL ศูนย์คอมพิวเตอร์ 24GHz/5.8GHz human presence sensor
9 SONOFF SNZB-06P SNZB-06P ศูนย์คอมพิวเตอร์ Zigbee occupancy sensor
10-13 Tuya TS0207 Aubess IH-K665 ศูนย์คอมพิวเตอร์ Water leak sensors (WL-01 to WL-04)
Device Location IP Address SNMP Community
OBH-UPS-01 (อาคารหมอบริกส์) OBH 194.1.1.50 OBHIoT
OBH-UPS-02 (อาคารหมอกัมพล) OBH 194.1.1.51 OBHIoT
OBH-UPS-03 (ระบบงานรังสี) OBH 194.1.1.52 OBHIoT
OBHMS-UPS-01 (แม่สาย) OBH-MS 194.2.1.50 OBHIoT
OBHCK-UPS-01 (เชียงของ) OBH-CK 194.3.1.50 OBHIoT
Device IP Address Notes
Trend Chiller Controller 194.1.1.60 -
Chiller Network (Mikrotik) 194.1.1.10 -
Category Count
Zigbee Coordinators 8
Water Level Sensors 6
Water Tank Lamps/Controllers 8
AC Magnetic Controllers 16 (10 installed, 6 pending)
IR Blasters 9 (6 installed, 3 pending)
Temperature/Humidity Sensors 18
Energy Monitors (3-Phase) 5
Solar Loggers/RS485 7
Pump Controllers 10
Medicine Carts 21
Zigbee Sensors 13
UPS Systems 5
CCTV Cameras 25
Other (Chime, LPG, Nitrous, etc.) ~15
Total ~166